Stocking packing for your waterous hale darley c entrifugal fire pump.
Fire pump packing.
But as the pump and packing start to set in you can expect a couple years of consistent and reliable service.
Thoroughly clean and inspect the stuffing box.
Packing adjustment will be more frequent at first.
Repacking and regular maintenance is import for protecting your building as well as preventing expensive repairs later.
Are inside the building they see the drip and think that.
Coat each new packing ring with pak lube go jo or some type of liquid soap.
Peerless fire pump installations ul listed ulc listed or fm approved deliver superior fire protection to facilities worldwide.
Proper pump packing installation.
166 32 0 add to cart.
Post navigation fire pump parts accessories availability hubbell launches a new line of metron fire pump controllers.
Products 6 sort by.
Tighten down the followers.
Feel the packing gland be careful of the rotating shaft to see if the packing gland is too hot or uneven which will result in damage to the pump shaft.
You ll be confident that your system is ready to operate with real time monitoring and the added benefit of alerts and alarms notifications that you can configure.
Peerless fireconnect allows you to access complete fire pump system information 24 7 anytime and anywhere via your smartphone tablet laptop or desktop.
Replace worn shaft sleeve if needed.
Never use anti seize or any metallic based compound on the pump packing.
We also offer kits from patterson and fair banks please contact us with your pump information for purchasing.
If you have any questions about replacing fire pump packing or would prefer we perform the service for you simply pick up the phone and call us at 302 652 4722.
Field tested products are designed for reliability and longevity and include a broad selection of pumps drives controls baseplates and accessories.
The packing gland should be placed on top of the packing.
Gain system design advantages by leveraging our expertise in evolving standards and local fire codes.
Centrifugal fire pump packing.
Waterous mechanical seal kit.
Most fire pumps will have six rings of packing.
Pentair aurora s commitment to fire suppression system performance and quality service goes beyond just 100 years of perfecting fire pump design.
Posted in fire pumps general information and tagged extend pump service life packing gland adjustments on april 8 2016 by admin.
263 43 0 add to cart.
Adjust the followers one flat or of a turn every 30 minutes or until the leakage is controlled.
Hale zm packing kit.
Waterous fire pump packing cmu 1993 up wtrs.